diálogos ELE

Determines the suitability of components and equipment for use or exposure in a salt-laden atmosphere. It has the status of a horizontal. IEC has superseded IEC as of 17 November , with the new standard harmonised with ISO Find the most up-to-date version of DS/IEC at Engineering

Author: Dujora Faezilkree
Country: Honduras
Language: English (Spanish)
Genre: Automotive
Published (Last): 18 November 2004
Pages: 42
PDF File Size: 4.87 Mb
ePub File Size: 8.97 Mb
ISBN: 518-6-32117-554-8
Downloads: 42464
Price: Free* [*Free Regsitration Required]
Uploader: Arashigami

Severities 3 to 6 were separated into a specific number of test cycles.

New Salt Mist / Corrosion standard IEC 60068-2-52

Test method 8 is the same as Test method 7 but using an acidified salt solution instead of a neutral salt solution. Salt mist to dry condition: The new version has renamed Severities 1 to 6 to test methods 1 — 6 68–52 also adding methods 7 and 8. By Admin November 17, There is now a flow chart included in the standard identifying the iecc required for each of the above mentioned Test methods.

Salt Spray Chamber While there have been some additions and changes iex the language used in defining the introduction, scope and references, the major changes are as follows: Severity 4 is now changed to Test method 4but remains the same 14 day test 2 cycles. Salt mist to dry condition: Follow Us facebook linkedin youtube.

The new version has renamed Severities 1 to 6 to test methods 1 — 6 while also 668-2-52 methods 7 and 8. Severity 5 is now changed to Test method 5but remains the same 28 day test 4 cycles.

  BSS84P DATASHEET PDF

Severity 5 is now changed to Test method 5but remains the same 28 day test 4 cycles. Severity 4 is now changed to Test method 4but remains the same 14 day test 2 cycles. Test method 7 is a new test with 8 hour cycles with a selection of the durations; 1 day 3 cycles2 days 6 cycles4 days 12 cycles10 days 30 cycles15 days 45 cycles20 days 60 cycles30 days 90 cycles50 days cycles and 60 days cycles. Severities 3 to 6 were separated into a specific number of test cycles.

Corrorsion climate alternating test units with controlled climate SC/UKWT 1000

Follow Us facebook linkedin youtube. Austest Laboratories is accredited for testing to the old and new versions of this standard. The general descriptions of the tests have changed In the version the salt mist tests were defined from Severities 1 to 6.

Severity 6 is now changed to Test method 6but remains the same 56 day test 8 cycles. Adelaide accreditation will be added shortly. Test method 8 is the same as Test method 7 but using an acidified salt solution instead of a neutral salt solution.

IEC | IEC Webstore | rural electrification

Test method 7 is a new test with 8 hour cycles with a selection of the durations; 1 day 3 cycles2 days 6 cycles4 days 12 cycles10 days 30 cycles15 days 45 cycles20 days 60 cycles30 days 90 cycles50 days cycles and 60 days cycles.

  HONEYWELL W7760C2017 PDF

Austest Laboratories is accredited for testing to the old and new versions of this standard.

Adelaide accreditation will be added shortly. Salt Spray Chamber While there have been some additions and changes to the language used in defining the introduction, scope and references, the major changes are as follows: The general descriptions of the tests have changed In the version the salt mist tests were defined from Severities 1 to 6. There is now a flow chart included in the standard identifying the parameters required for each of the above mentioned Test methods.

While there have been some additions and changes to the language used in defining the introduction, scope and references, the major changes are as follows:.

Environmental Test Services – UKAS Accredited Climatic Tests

Severity 3 is now changed to Test method 3but remains the same 7 day test 1 cycle. While there have been some additions and changes to the language used in defining the introduction, scope and references, the major changes are as follows:.

Severity 6 is now changed to Test method 6but remains the same 56 day test 8 cycles. Severity 3 is now changed to Test method 3but remains the same 7 day test 1 cycle. By Admin November 17,